In our first part of this interview series, we discussed why concrete abrasion is such an issue for concrete construction and how it’s often treated. (For all the details, give it a read!) Most of the solutions discussed were shown to be complicated and ineffective. But we ended on a positive note, briefly talking about a solution that could offer a more worry-free way to increase concrete abrasion resistance.
That solution turned out to be Hard-Cem®. As the only integral concrete hardener on the market, it offers a unique advantage to construction workers. With Hard-Cem, workers only have to add it to the concrete mix during batching, and that’s it. Hard-Cem doesn’t need a complicated application process and has been shown to be effective at what it does. And what it does is double your concrete’s wear life while increasing your concrete’s resistance to abrasion and erosion.
But is all that too good to be true? How does Hard-Cem actually perform? To look into it, we asked our previous contributors, Technical Director Jeff Bowman and Kryton Western Canada Territory Manager John Andersen, to give us the details.
Jeff: To answer that, let’s first review some of the test methods you could use for abrasion resistance.
There are several established test methods published by ASTM. But the one I’d like to highlight today is ASTM C627 (also known as the Robinson floor test based on the machine that is used for the testing).
Now, what’s really interesting about this test is that it applies a much higher load and a much longer test duration than many of the other methods that people might use.
And early in the days of Hard-Cem’s development, Dr. Rusty Morgan, working with AMEC, recommended using this test and adapting it to increase the load and the test time to make it more useful as a test for the abrasion resistance of concrete. One of the advantages of this adaption is that because the test panel is quite large, it allows you to get a more realistic look at real-world finishing conditions that you might use for your concrete.
Essentially, during the test, wheels rotate around the concrete, allowing you to measure the depth of wear directly just by using a pair of depth calipers.
A common result for this is a very straightforward, plain concrete mix of 25 MPa [3,000 psi] with about 1.8 mm of wear depth. And after 5,000 revolutions, the depth of wear of the Hard-Cem concrete is reduced by about half compared to your plain concrete. So it creates a very significant increase in the abrasion resistance of that slab.