Building in Prince George recognized as the most airtight industrial building in North America

 

The Wood Innovation Research Lab in Prince George, appears to be nothing more than a modern cedar and black-metal building, but look past the cladding and you’ll find an engineering feat that has earned it the recognition as the most airtight industrial building on the continent.

The University of Northern British Columbia building has received Passive House certification, making it the first of its type in North America to meet the internationally recognized standards for energy efficiency.

Guido Wimmers, chairman of the Integrated Wood Design Program at UNBC, said the building is very efficient and cuts heating and cooling bills by up to 90 per cent in a central B.C. climate where temperatures range from -30 C in winter to 30 C in summer.

“To get to Passive House standards in this climate, with this geometry, that was a big challenge and hasn’t been done, to the best of my knowledge. There are three or four industrial buildings worldwide,” he said.

Click here to sign-up and receive the Weekly Round Up in your inbox every Saturday

There are Passive House organizations around the world advocating for high-performance buildings in design, construction and livability. Thousands of Canadian homes have been certified by the group indicating they have met limits for heat, energy use and being airtight.

The research building is 30 metres by 30 metres, with walls that are a half-metre thick and contain blown-in mineral wool insulation.

Generally construction costs about five per cent more for passive buildings, but the university is the owner and it’s also interested in the operation costs, said Wimmers.

“The initial investment is higher, true, but the actually monthly costs of ownership are lower. And that’s always the goal. It has to be cost-efficient, otherwise nobody would do it.”

It will cost about $1,000 a year to heat, Wimmers said.

“A normal building of this type would have had a heating bill of $16,000, or something like that.”

The biggest challenge to obtaining the certification was a large overhead door that allows material to be brought into the research lab.